文章来源:http://www.trcables.com/ 作者:上海嗨润 发布时间::2018-01-19 14:10 浏览次数:次
Application
These armoured cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.
Standards
DIN 89159/98
IEC 60092-351/375/359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction
Conductors: Stranded copper conductor.
Insulation: HEPR.
Cabling Element: Pair.
Armour: Copper wire braid.
Outer Sheath: LSOH (SHF1).
Core Identification
Pair: white/ blue with printed pair number and core number.
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 6×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
Part No. |
Construction |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall |
Nominal Weight kg/km |
MRE-3GCH-1P0.75 |
1×2×0.75 |
0.5 |
1.2 |
8.5 |
90 |
MRE-3GCH-2P0.75 |
2×2×0.75* |
0.5 |
1.3 |
9.5 |
130 |
MRE-3GCH-4P0.75 |
4×2×0.75 |
0.5 |
1.4 |
13.0 |
230 |
MRE-3GCH-7P0.75 |
7×2×0.75 |
0.5 |
1.8 |
15.5 |
340 |
MRE-3GCH-10P0.75 |
10×2×0.75 |
0.5 |
1.9 |
18.5 |
470 |
MRE-3GCH-14P0.75 |
14×2×0.75 |
0.5 |
2.0 |
21.0 |
610 |
MRE-3GCH-19P0.75 |
19×2×0.75 |
0.5 |
2.1 |
23.5 |
770 |
MRE-3GCH-24P0.75 |
24×2×0.75 |
0.5 |
2.2 |
26.5 |
950 |
*: 2 pairs are assembled as a quad.